| General | |
|---|---|
| Frequency coverage | 0.03–60.000000 MHz* *0.03–29.999999 MHz only for Asia version; specifications guaranteed 0.1–29.99 MHz and 50–54 MHz only. |
| Mode | USB, LSB, CW, RTTY, AM, FM |
| Number of memory channels | 101 (99 regular, 2 scan edges) |
| Frequency stability | Less than ±7 ppm from 1 min. to 60 min. after power on. After that rate of stability less than ±1 ppm/hr. at +25°C (+77°F). Temperature fluctuations 0°C to +50°C (+32°F to +122°F) less than ±5 ppm. |
| Power supply requirement | 13.8 V DC ±15% (negative ground) |
| Current drain (at 13.8 V DC) Standby Max. audio |
0.9 A 1.1 A |
| Antenna connector | SO-239 (50 Ω), push connection terminal (500 Ω) |
| Dimensions | 241(W) × 94(H) × 229(D) mm 91⁄2(W) × 31⁄16(H) × 91⁄32(D) in |
| Weight (approx.) | 3.0 kg; 6 lb 10 oz |
| REMOTE connector | RS-232C D-sub 9-pin |
| CI-V connector | 2-conductor 3.5 (d) mm (1⁄8″) |
| Receiver | |||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Receive system | Triple-conversion super heterodyne system | ||||||||||||||||||||||||
| Intermediate frequencies
|
*May differ according to selected IF filter. |
||||||||||||||||||||||||
| Sensitivity |
|
||||||||||||||||||||||||
| SQL sensitivity (threshold) |
*1 Preamp 1: ON *2 Preamp 2: ON |
||||||||||||||||||||||||
| Selectivity SSB, CW, RTTY AM FM |
More than 2.1 kHz/–6 dB Less than 4.0 kHz/–60 dB More than 6 kHz/–6 dB Less than 20 kHz/–50 dB More than 12 kHz/–6 dB Less than 30 kHz/–40 dB |
||||||||||||||||||||||||
| Spurious and image rejection ratio | More than 70 dB (except IF through/50 MHz band) | ||||||||||||||||||||||||
| Audio output power | More than 2.0 W at 10% distortion with an 8Ω load | ||||||||||||||||||||||||
| PHONES connector | 3-conductor 6.35 (d) mm (1⁄4″) | ||||||||||||||||||||||||
| External SP connector | 2-conductor 3.5 (d) mm (1⁄8″)/8Ω | ||||||||||||||||||||||||
The IC-R75 has been tested to and passed the MIL-STD requirements and
strict environmental standards for shock (MIL 810C, D, E) and vibration
(MIL 810C, D, E).